EDR.. Explosion-proof Motors
Features
As a system operator, special regulations apply to areas with explosive gas/air and dust/air mixtures. Of course, we also follow these regulations when developing or improving explosion-proof drive technology. You can rely on our many years of experience and knowledge.
Advantages
Stay flexible
· Our explosion-proof motors can be reliably operated in both hazardous areas, in gas and dust atmospheres.
In combination with frequency converters
Compared to AC asynchronous motors with explosion protection type "d" (flameproof enclosure according to EN 60079-1), the advantages of this combination can be summarized as follows:
Efficiency
Low weight
Delivery time, high availability
SEW frequency converter operation certification
Suitable for pump and fan drives
Delivery by the manufacturer who supplies all components
Compliance with guidelines must be ensured, especially in areas with potentially explosive gas/air and dust/air mixtures. Thanks to our many years of experience and expertise in this field, we adhere to the relevant guidelines.
· Operation on certified frequency converters
· In addition, brake motors for Category 3, Division 2 areas are also available
· Suitable operation on frequency converters is confirmed on the nameplate
|
Area |
Motor Type |
Protaction Type |
MOVITRAC® B |
MOVIDRIVE® B |
MOVIMOT® |
|
1 |
EDR ../ 2G |
“E”(EN 60079-7) |
x* |
x |
- |
|
2 |
EDR ../ 3GD |
“NA”(EN60079-15,No sparks) |
x* |
x* |
- |
|
21 |
EDR ../ 2GD |
“TB”(EN60079-31,Dust explosion proof) |
x* |
x |
- |
|
22 |
EDR ../ 3GD |
“TC”(EN60079-31,Dust explosion proof) |
x* |
x* |
x* |
|
EDR ../ 3D |
|
Output Options |
|
|
Output Options |
/Foot and flange mount designs for standard motors |
|
Mechanical Accessories |
|
|
Brake |
All sizes of Class 3 and HAZLOC-NA® (motor size up to size 225) |
|
Brake hand release |
HF、HR |
|
Backstop |
/RS |
|
Decentralized installation |
MOVISWITCH® 以及MOVIMOT® II3D |
|
Temperature sensor / temperature detection |
|
|
Thermomotor protection |
/TF |
|
Temperature detection |
/PT、/KY |
|
Encoder |
|
|
Additional encoder EDR71-132 |
/AS7W、/AS7Y、/EV7.、 |
|
Additional encoder EDR160-280 |
/EG7S、/EG7R、/EG7C、/AG7W、/AG7Y、/EV7.、 |
|
Additional encoder EDR315 |
/EH7S / AH7Y |
|
Adapter ring |
/EG7A、/XV.A、/XH.A |
|
Ventilation |
|
|
Forced cooling fan |
/VE |
|
Other options |
|
|
Second bearing end |
/2W |
Technical Data
|
Design |
IECEx |
Explosion-proof protection |
Zones |
4-pole type/size |
IE class |
Power range |
|
/ 3D and/ 3GD |
/ 3GC and / 3GDc |
II3G、EPL Gc、T3、"nA" |
2 |
DR63*
EDRS 71 – 80
EDRE 80 – 315
|
-
IE1
IE2
|
0.12 – 0.25
0.25 – 0.55
0.75 – 45
0.75 – 185/200
|
|
II3D、EPL Dc、IIIB、IIIC
T120 ℃/T140° C、„tc“
|
22 |
|||||
|
/ 2G and/ 2GD |
/ 2GB and/ 2GDb |
II2G、EPL Gb、T3、"e" |
1 |
eDR 63
EDRS 71 – 80
EDRE 80 – 225
|
IE1
IE2
|
0.12 - 0.25
0.25 – 0.55
0.75 – 37
|
|
II2D,工程零件表 Db,IIIC T120 °C “tb” |
21 |
|||||
|
/ 2G and/ 2GD |
/ 2GB and/ 2GDb |
II2G、EPL Gb、T4、"e" |
1 |
EDRS 71 – 80
EDRE 80
|
IE1
IE2
|
0.25 – 0.55
0.75
|
|
II2D,Engineering Parts List Db,IIIC T120 °C “tb” |
21 |
|||||
|
1. *Only in compliance with explosion-proof directives |
||||||
|
Division 2 |
4-pole type/size |
IE class |
Power range |
|
Class I
Groups B, C and D
T3 for operation on FI T3C for operation on power supply systems T3B / C brake motors on supply systems
|
EDRS 71 – 80
EDRE 80 – 225
|
IE1
高(IE2)
|
0.18 – 0.55
0.75 – 45
|
|
Class II
Groups F and G
|
Application Areas
1. Wastewater and sewage treatment plants
2. Material handling applications
3. Process applications in the chemical and pharmaceutical industries
Application Examples
· Angular transfer units
· Extruders
· Travel and hoisting drives in tower cranes
· Screw conveyors
· Belt conveyors
· Lifting stations
· Chain conveyors
· Freight elevators
· Pallet conveyors
· Gantry cranes
· Presses
· Pumps and fans
· Roller conveyors
· Rotating tables
· Scissor lifting tables
· Fans